{"id":1048,"date":"2019-02-07T14:46:03","date_gmt":"2019-02-07T14:46:03","guid":{"rendered":"https:\/\/www.matradiagnosztika.hu\/?page_id=1048"},"modified":"2020-04-27T16:23:37","modified_gmt":"2020-04-27T14:23:37","slug":"destructive-material-testing-dt","status":"publish","type":"page","link":"https:\/\/www.matradiagnosztika.com\/en\/services\/destructive-material-testing-dt\/","title":{"rendered":"Destructive material testing (DT)"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; fullwidth=&#8221;on&#8221; _builder_version=&#8221;3.19.6&#8243; top_divider_color=&#8221;#ffffff&#8221; bottom_divider_color=&#8221;#f1f1f1&#8243; bottom_divider_height=&#8221;50px&#8221; global_module=&#8221;1035&#8243; saved_tabs=&#8221;all&#8221;][et_pb_fullwidth_header title=&#8221;M\u00e1tra-Diagnosztika Ltd.&#8221; text_orientation=&#8221;center&#8221; admin_label=&#8221;M\u00e1tra Diagnosztika Ltd.&#8221; _builder_version=&#8221;3.23.3&#8243; title_level=&#8221;h2&#8243; title_font=&#8221;|700|||||||&#8221; title_font_size=&#8221;40px&#8221; content_font=&#8221;|700||on|||||&#8221; content_font_size=&#8221;20px&#8221; content_letter_spacing=&#8221;1px&#8221; content_line_height=&#8221;1.5em&#8221; subhead_font=&#8221;|700||on|||||&#8221; subhead_letter_spacing=&#8221;1px&#8221; subhead_line_height=&#8221;1.5em&#8221; background_color=&#8221;rgba(0,0,0,0.6)&#8221; background_image=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/manufactures-2906874_1920.jpg&#8221; background_blend=&#8221;overlay&#8221; title_font_size_tablet=&#8221;40px&#8221; title_font_size_phone=&#8221;30px&#8221; title_font_size_last_edited=&#8221;on|phone&#8221;]<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-51 alignnone size-full\" src=\"https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/logo-ikon.jpg\" alt=\"\" width=\"126\" height=\"84\" \/><\/p>\n<p><b>Destructive and Non-Destructive material testing<\/b><\/p>\n<p>[\/et_pb_fullwidth_header][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;3.22.3&#8243; background_image=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/textured-background-6.png&#8221; parallax=&#8221;on&#8221; parallax_method=&#8221;off&#8221; custom_padding=&#8221;54px|0px|15px|0px|false|false&#8221; top_divider_height=&#8221;61px&#8221; bottom_divider_color=&#8221;#ffffff&#8221;][et_pb_row _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243; border_color_left=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Services: Destructive material testing (DT)&#8221; _builder_version=&#8221;3.27.4&#8243; text_font=&#8221;||||||||&#8221; header_font=&#8221;Roboto Condensed|700||on|||||&#8221; header_2_font=&#8221;|700|||||||&#8221; header_2_font_size=&#8221;38px&#8221; text_orientation=&#8221;center&#8221; header_font_size_tablet=&#8221;&#8221; header_font_size_phone=&#8221;32px&#8221; header_font_size_last_edited=&#8221;on|phone&#8221; header_2_font_size_tablet=&#8221;38px&#8221; header_2_font_size_phone=&#8221;30px&#8221; header_2_font_size_last_edited=&#8221;on|phone&#8221; locked=&#8221;off&#8221;]<\/p>\n<h2>Services:<\/h2>\n<h1><strong>Destructive material testing (DT)<\/strong><\/h1>\n<p>[\/et_pb_text][et_pb_divider divider_weight=&#8221;4px&#8221; _builder_version=&#8221;3.19.3&#8243; max_width=&#8221;100px&#8221; module_alignment=&#8221;center&#8221;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Tensile test&#8221; _builder_version=&#8221;4.4.4&#8243; header_font=&#8221;||||||||&#8221; header_4_font=&#8221;||||||||&#8221; header_4_line_height=&#8221;1.5em&#8221; border_color_left=&#8221;#079508&#8243;]<\/p>\n<h4><strong>Tensile test:\u00a0 <\/strong><\/h4>\n<p>A sample is subjected to a controlled tension until failure, to identify how the material will react under forces.<\/p>\n<p><strong><em>ZD 100 szak\u00edt\u00f3g\u00e9p, maximum 1000 kN,<\/em><\/strong><\/p>\n<p><strong><em>Zwick\/Roell Z150 tensile testing machine, maximum load 150 kN.<\/em><\/strong><\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_2,1_2&#8243; _builder_version=&#8221;4.4.4&#8243; hover_enabled=&#8221;0&#8243; locked=&#8221;off&#8221; disabled_on=&#8221;on|on|on&#8221; disabled=&#8221;on&#8221;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.4.4&#8243;][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/uj1.jpg&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;3.23&#8243; max_width=&#8221;60%&#8221; max_width_tablet=&#8221;&#8221; max_width_phone=&#8221;&#8221; max_width_last_edited=&#8221;on|desktop&#8221;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.4.4&#8243;][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2020\/04\/zwroell-800.jpeg&#8221; title_text=&#8221;zwroell-800&#8243; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;4.4.4&#8243; max_width=&#8221;60%&#8221; max_width_tablet=&#8221;&#8221; max_width_phone=&#8221;&#8221; max_width_last_edited=&#8221;on|desktop&#8221;][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.4.4&#8243; hover_enabled=&#8221;0&#8243; disabled_on=&#8221;off|off|off&#8221; locked=&#8221;off&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.4.4&#8243;][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2020\/04\/zwroell-800.jpeg&#8221; title_text=&#8221;zwroell-800&#8243; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;4.4.4&#8243; max_width=&#8221;60%&#8221; max_width_tablet=&#8221;&#8221; max_width_phone=&#8221;&#8221; max_width_last_edited=&#8221;on|desktop&#8221;][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_divider divider_position=&#8221;bottom&#8221; divider_weight=&#8221;7px&#8221; _builder_version=&#8221;3.19.3&#8243;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Impact test&#8221; _builder_version=&#8221;3.27.4&#8243; header_font=&#8221;||||||||&#8221; header_4_font=&#8221;||||||||&#8221; header_4_line_height=&#8221;1.5em&#8221; border_color_left=&#8221;#079508&#8243;]<\/p>\n<h4><strong>Impact test:<\/strong><\/h4>\n<p>Shows the amount of energy absorbed by a material during fracture (toughness).<\/p>\n<p><strong><em>\u00dcT 30 impact testing machine with max. of 300 J energy.<\/em><\/strong><\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/kem-uto.jpg&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;3.23&#8243; max_width=&#8221;80%&#8221;][\/et_pb_image][et_pb_divider divider_position=&#8221;bottom&#8221; divider_weight=&#8221;7px&#8221; _builder_version=&#8221;3.19.3&#8243;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Bend test&#8221; _builder_version=&#8221;4.4.4&#8243; header_font=&#8221;||||||||&#8221; header_4_font=&#8221;||||||||&#8221; header_4_line_height=&#8221;1.5em&#8221; border_color_left=&#8221;#079508&#8243;]<\/p>\n<h4><strong>Bend test:<\/strong><\/h4>\n<p>Strength of the material by bending it over a given radius.<\/p>\n<p><strong><em>ZD 100 tensile testing machine with max of 1000 kN power load<\/em><\/strong><strong><em><\/em><\/strong><\/p>\n<p><strong><em>Welding bend test with\u00a0 max of 4000 kN power load.<\/em><\/strong><\/p>\n<p>[\/et_pb_text][et_pb_divider divider_position=&#8221;bottom&#8221; divider_weight=&#8221;7px&#8221; _builder_version=&#8221;3.19.3&#8243;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Flattening test&#8221; _builder_version=&#8221;4.4.4&#8243; header_font=&#8221;||||||||&#8221; header_4_font=&#8221;||||||||&#8221; header_4_line_height=&#8221;1.5em&#8221; border_color_left=&#8221;#079508&#8243;]<\/p>\n<h4><strong>Flattening test:<\/strong><\/h4>\n<p>The compression strength of the tube to find out if it will rupture upon flattening.<\/p>\n<p><strong><em>ZD 100 tensile testing machine with max of 1000 kN power load<\/em><\/strong><\/p>\n<p>[\/et_pb_text][et_pb_divider divider_position=&#8221;bottom&#8221; divider_weight=&#8221;7px&#8221; _builder_version=&#8221;3.19.3&#8243;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Ring expanding test&#8221; _builder_version=&#8221;4.4.4&#8243; header_font=&#8221;||||||||&#8221; header_4_font=&#8221;||||||||&#8221; header_4_line_height=&#8221;1.5em&#8221; border_color_left=&#8221;#079508&#8243;]<\/p>\n<h4><strong>Ring expanding test:<\/strong><\/h4>\n<p>A test ring is expanded by a mandrel until fracture occurs to reveal defects on the surfaces and within the tube wall.<\/p>\n<p><strong><em>ZD 100 tensile testing machine with max of 1000 kN power load<\/em><\/strong><\/p>\n<p>[\/et_pb_text][et_pb_divider divider_position=&#8221;bottom&#8221; divider_weight=&#8221;7px&#8221; _builder_version=&#8221;3.19.3&#8243;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Hardness testing HT&#8221; _builder_version=&#8221;3.27.4&#8243; header_font=&#8221;||||||||&#8221; header_4_font=&#8221;||||||||&#8221; header_4_line_height=&#8221;1.5em&#8221; border_color_left=&#8221;#079508&#8243;]<\/p>\n<h4><strong>Hardness testing HT:<\/strong><\/h4>\n<p>The resistance to indentation and it is determined by measuring the permanent depth of the indentation.<\/p>\n<p><strong><em>Zwick-Roell ZHV 20 hardness tester by Knoop &amp; Vickers (HV0,1-HV20),<\/em><\/strong><strong><em>\u00a0\u00a0\u00a0\u00a0\u00a0 <\/em><\/strong><\/p>\n<p><strong><em>HPO 250 hardness tester by Brinell &amp; Vickers.<\/em><\/strong><\/p>\n<p><strong><em>HPO 3000 hardness tester by Brinell,<\/em><\/strong><\/p>\n<p><strong><em>Hanemann microhardness testing by Vickers with Neophot 21 microscope.<\/em><\/strong><\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_2,1_2&#8243; use_custom_gutter=&#8221;on&#8221; gutter_width=&#8221;2&#8243; make_equal=&#8221;on&#8221; custom_padding_last_edited=&#8221;on|phone&#8221; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;12px|0px|17px|0px|false|false&#8221; custom_padding_tablet=&#8221;&#8221; custom_padding_phone=&#8221;&#8221; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/uj.jpg&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;3.23&#8243;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding_tablet=&#8221;&#8221; custom_padding_phone=&#8221;|||&#8221; custom_padding_last_edited=&#8221;on|phone&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/P1010267.jpg&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;3.23&#8243; custom_margin_tablet=&#8221;&#8221; custom_margin_phone=&#8221;&#8221; custom_margin_last_edited=&#8221;on|desktop&#8221; custom_padding_tablet=&#8221;&#8221; custom_padding_phone=&#8221;&#8221; custom_padding_last_edited=&#8221;on|phone&#8221;][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;3.25&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_divider divider_position=&#8221;bottom&#8221; divider_weight=&#8221;7px&#8221; _builder_version=&#8221;3.19.3&#8243;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Portable hardness testing HT&#8221; _builder_version=&#8221;3.27.4&#8243; header_font=&#8221;||||||||&#8221; header_4_font=&#8221;||||||||&#8221; header_4_line_height=&#8221;1.5em&#8221; border_color_left=&#8221;#079508&#8243;]<\/p>\n<h4><strong>Portable hardness testing HT:<\/strong><\/h4>\n<p>The method is pretty much the same as it says above, but in this case the unit can be taken to site and the test can be done locally.<\/p>\n<p><strong><em>Krautkr\u00e4mer TIV with power load of 50 N.<\/em><\/strong><\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/uj3.jpg&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;3.23&#8243; max_width=&#8221;80%&#8221;][\/et_pb_image][et_pb_divider divider_position=&#8221;bottom&#8221; divider_weight=&#8221;7px&#8221; _builder_version=&#8221;3.19.3&#8243;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Metallographic testing&#8221; _builder_version=&#8221;3.27.4&#8243; header_font=&#8221;||||||||&#8221; header_4_font=&#8221;||||||||&#8221; header_4_line_height=&#8221;1.5em&#8221; border_color_left=&#8221;#079508&#8243;]<\/p>\n<h4><strong>Metallographic testing:<\/strong><\/h4>\n<p>Microscopic study of the physical structure and components of metals in-lab or on-site (replica).<\/p>\n<p><strong><em>PRESI automatic grinding and polishing<\/em><\/strong> <strong><em>machines, <\/em><\/strong><\/p>\n<p><strong><em>NEOPHOT 21<\/em><\/strong> <strong><em>metal microscope,<\/em><\/strong><\/p>\n<p><strong><em>Zeiss Axio Imager metal microscope,<\/em><\/strong><\/p>\n<p><strong><em>PRESI replica kit and a portable microscope<\/em><\/strong>.<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/metallografia.jpg&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;3.23&#8243; max_width=&#8221;80%&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;Metallogr\u00e1fiai vizsg\u00e1lat&#8221; _builder_version=&#8221;3.27.4&#8243; header_font=&#8221;||||||||&#8221; header_4_font=&#8221;||||||||&#8221; header_4_line_height=&#8221;1.5em&#8221; border_color_left=&#8221;#079508&#8243; locked=&#8221;off&#8221;]<\/p>\n<h4><strong>Determination of Ferrite content by metallographic method:<\/strong><\/h4>\n<p>Within the process, the samples are prepared for the tissue structure test. The method is colour tint etching, being used to get the texture, what is recorded with a microscope. The evaluation is based on an image analysing software, which is reported in documentation.[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/06\/pc_41_96-ferrit.jpg&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;3.23.3&#8243; max_width=&#8221;80%&#8221; locked=&#8221;off&#8221;][\/et_pb_image][et_pb_divider divider_position=&#8221;bottom&#8221; divider_weight=&#8221;7px&#8221; _builder_version=&#8221;3.19.3&#8243;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Erichsen cupping test&#8221; _builder_version=&#8221;3.27.4&#8243; header_font=&#8221;||||||||&#8221; header_4_font=&#8221;||||||||&#8221; header_4_line_height=&#8221;1.5em&#8221; border_color_left=&#8221;#079508&#8243;]<\/p>\n<h4><strong>Erichsen cupping test:<\/strong><\/h4>\n<p>Ductility test to evaluate the ability of metallic sheets and strips to undergo plastic deformation in stretch forming.<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/erichensen.jpg&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;3.23&#8243; max_width=&#8221;80%&#8221;][\/et_pb_image][et_pb_divider divider_position=&#8221;bottom&#8221; divider_weight=&#8221;7px&#8221; _builder_version=&#8221;3.19.3&#8243;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;70px|0px|55px|0px|false|false&#8221; border_color_top=&#8221;#079508&#8243; border_color_bottom=&#8221;#079508&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_image src=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/logo2.png&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;3.23&#8243;][\/et_pb_image][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;3.19.6&#8243; background_color=&#8221;rgba(0,0,0,0.6)&#8221; background_image=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/architecture-2267789_1920.jpg&#8221; background_blend=&#8221;overlay&#8221; custom_padding=&#8221;75px|0px|54px|0px|false|false&#8221; top_divider_color=&#8221;#F1F1F1&#8243; top_divider_height=&#8221;50px&#8221; top_divider_flip=&#8221;vertical&#8221; global_module=&#8221;1026&#8243; saved_tabs=&#8221;all&#8221;][et_pb_row _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;27px|0px|11px|0px|false|false&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Fields of application&#8221; _builder_version=&#8221;3.27.4&#8243; text_font=&#8221;||||||||&#8221; header_font=&#8221;||||||||&#8221; header_3_font=&#8221;|700|||||||&#8221; header_3_font_size=&#8221;35px&#8221; text_orientation=&#8221;center&#8221; background_layout=&#8221;dark&#8221; header_3_font_size_tablet=&#8221;&#8221; header_3_font_size_phone=&#8221;30px&#8221; header_3_font_size_last_edited=&#8221;on|phone&#8221;]<\/p>\n<h3>Fields of application<\/h3>\n<p>[\/et_pb_text][et_pb_divider divider_weight=&#8221;4px&#8221; _builder_version=&#8221;3.19.3&#8243; max_width=&#8221;130px&#8221; module_alignment=&#8221;center&#8221;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_3,1_3,1_3&#8243; make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243;][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;3.25&#8243; background_color=&#8221;#ffffff&#8221; custom_padding=&#8221;|||&#8221; custom_css_main_element=&#8221;border-bottom: 5px solid #03940B;&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_blurb title=&#8221;OIL, GAS AND PETROCHEMICAL INDUSTRY&#8221; image=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/petrolkemia.jpg&#8221; admin_label=&#8221;OIL, GAS AND PETROCHEMICAL INDUSTRY&#8221; _builder_version=&#8221;3.19.12&#8243; header_font=&#8221;|700|||||||&#8221; header_font_size=&#8221;20px&#8221; body_font=&#8221;||||||||&#8221; body_font_size=&#8221;18px&#8221; body_line_height=&#8221;1em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||0px&#8221; custom_padding=&#8221;30px|20px|30px|20px&#8221; animation=&#8221;off&#8221; custom_css_blurb_title=&#8221;padding-bottom: 20px;&#8221; border_radii_image=&#8221;on|1px|1px|1px|1px&#8221; border_width_all_image=&#8221;1px&#8221; border_color_all_image=&#8221;#000000&#8243;]<\/p>\n<p>Tank inspection<\/p>\n<p>Pressure vessel inspection<\/p>\n<p>Pipelines<\/p>\n<p>Maintenance projects<\/p>\n<p>Condition detection<\/p>\n<p>Corrosion monitoring<\/p>\n<p>Other areas<\/p>\n<p>[\/et_pb_blurb][\/et_pb_column][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;3.25&#8243; background_color=&#8221;#ffffff&#8221; custom_padding=&#8221;|||&#8221; custom_css_main_element=&#8221;border-bottom: 5px solid #03940B;&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_blurb title=&#8221;Automotive industry&#8221; image=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/autoipar.jpg&#8221; admin_label=&#8221;Automotive industry&#8221; _builder_version=&#8221;3.19.12&#8243; header_font=&#8221;|700|||||||&#8221; header_font_size=&#8221;20px&#8221; body_font=&#8221;||||||||&#8221; body_font_size=&#8221;18px&#8221; body_line_height=&#8221;1em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||0px&#8221; custom_padding=&#8221;30px|20px|30px|20px&#8221; animation=&#8221;off&#8221; custom_css_blurb_title=&#8221;padding-bottom: 20px;&#8221; border_radii_image=&#8221;on|1px|1px|1px|1px&#8221; border_width_all_image=&#8221;1px&#8221; border_color_all_image=&#8221;#000000&#8243;]<\/p>\n<p>Casting<\/p>\n<p>Welding seam<\/p>\n<p>Elemental composition<\/p>\n<p>Mechanical tests<\/p>\n<p>Other areas<\/p>\n<p>[\/et_pb_blurb][\/et_pb_column][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;3.25&#8243; background_color=&#8221;#ffffff&#8221; custom_padding=&#8221;|||&#8221; custom_css_main_element=&#8221;border-bottom: 5px solid #03940B;&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_blurb title=&#8221;Power engineering &#038; steel structures&#8221; image=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/energetika.jpg&#8221; admin_label=&#8221;Power engineering &#038; steel structures&#8221; _builder_version=&#8221;3.19.12&#8243; header_font=&#8221;|700|||||||&#8221; header_font_size=&#8221;20px&#8221; body_font=&#8221;||||||||&#8221; body_font_size=&#8221;18px&#8221; body_line_height=&#8221;1em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||0px&#8221; custom_padding=&#8221;30px|20px|30px|20px&#8221; animation=&#8221;off&#8221; custom_css_blurb_title=&#8221;padding-bottom: 20px;&#8221; border_radii_image=&#8221;on|1px|1px|1px|1px&#8221; border_width_all_image=&#8221;1px&#8221; border_color_all_image=&#8221;#000000&#8243;]<\/p>\n<p>Mining machines<\/p>\n<p>Power plant\u2019s pipelines<\/p>\n<p>Conveyor belts<\/p>\n<p>Turbines<\/p>\n<p>Inspection and condition detection of steel structures<\/p>\n<p>Other areas<\/p>\n<p>[\/et_pb_blurb][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_3,1_3,1_3&#8243; make_equal=&#8221;on&#8221; _builder_version=&#8221;3.25&#8243;][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;3.25&#8243; background_color=&#8221;#ffffff&#8221; custom_padding=&#8221;|||&#8221; custom_css_main_element=&#8221;border-bottom: 5px solid #03940B;&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_blurb title=&#8221;Elemental composition &#038; specifics&#8221; image=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/anyag.jpg&#8221; admin_label=&#8221;Elemental composition &#038; specifics&#8221; _builder_version=&#8221;4.4.4&#8243; header_font=&#8221;|700|||||||&#8221; header_font_size=&#8221;20px&#8221; body_font=&#8221;||||||||&#8221; body_font_size=&#8221;18px&#8221; body_line_height=&#8221;1em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||0px&#8221; custom_padding=&#8221;30px|20px|30px|20px&#8221; animation=&#8221;off&#8221; custom_css_blurb_title=&#8221;padding-bottom: 20px;&#8221; border_radii_image=&#8221;on|1px|1px|1px|1px&#8221; border_width_all_image=&#8221;1px&#8221; border_color_all_image=&#8221;#000000&#8243;]<\/p>\n<p>Spectroscope<\/p>\n<p>LRUT \u2013 long range ultrasonic testing<\/p>\n<p>APR \u2013 heat exchanger inspection<\/p>\n<p>Other areas<\/p>\n<p>[\/et_pb_blurb][\/et_pb_column][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;3.25&#8243; background_color=&#8221;#ffffff&#8221; custom_padding=&#8221;|||&#8221; custom_css_main_element=&#8221;border-bottom: 5px solid #03940B;&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_blurb title=&#8221;Electrical industry&#8221; image=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/elektronika.jpg&#8221; admin_label=&#8221;Electrical industry&#8221; _builder_version=&#8221;3.19.12&#8243; header_font=&#8221;|700|||||||&#8221; header_font_size=&#8221;20px&#8221; body_font=&#8221;||||||||&#8221; body_font_size=&#8221;18px&#8221; body_line_height=&#8221;1em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||0px&#8221; custom_padding=&#8221;30px|20px|30px|20px&#8221; animation=&#8221;off&#8221; custom_css_blurb_title=&#8221;padding-bottom: 20px;&#8221; border_radii_image=&#8221;on|1px|1px|1px|1px&#8221; border_width_all_image=&#8221;1px&#8221; border_color_all_image=&#8221;#000000&#8243;]<\/p>\n<p>Radiographic inspection<\/p>\n<p>Wire harnesses and bindings<\/p>\n<p>Other areas<\/p>\n<p>[\/et_pb_blurb][\/et_pb_column][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;3.25&#8243; background_color=&#8221;#ffffff&#8221; custom_padding=&#8221;|||&#8221; custom_css_main_element=&#8221;border-bottom: 5px solid #03940B;&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_blurb title=&#8221;Welding procedure test&#8221; image=&#8221;https:\/\/www.matradiagnosztika.com\/wp-content\/uploads\/2019\/01\/heggesztes.jpg&#8221; admin_label=&#8221;Welding procedure test&#8221; _builder_version=&#8221;3.19.12&#8243; header_font=&#8221;|700|||||||&#8221; header_font_size=&#8221;20px&#8221; body_font=&#8221;||||||||&#8221; body_font_size=&#8221;18px&#8221; body_line_height=&#8221;1em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||0px&#8221; custom_padding=&#8221;30px|20px|30px|20px&#8221; animation=&#8221;off&#8221; custom_css_blurb_title=&#8221;padding-bottom: 20px;&#8221; border_radii_image=&#8221;on|1px|1px|1px|1px&#8221; border_width_all_image=&#8221;1px&#8221; border_color_all_image=&#8221;#000000&#8243;]<\/p>\n<p>Specification and qualification of welding procedures<\/p>\n<p>Other areas<\/p>\n<p>[\/et_pb_blurb][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Destructive and Non-Destructive material testingServices: Destructive material testing (DT)Tensile test:\u00a0 A sample is subjected to a controlled tension until failure, to identify how the material will react under forces. ZD 100 szak\u00edt\u00f3g\u00e9p, maximum 1000 kN, Zwick\/Roell Z150 tensile testing machine, maximum load 150 kN.Impact test: Shows the amount of energy absorbed by a material during [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1103,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-1048","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.matradiagnosztika.com\/en\/wp-json\/wp\/v2\/pages\/1048","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.matradiagnosztika.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.matradiagnosztika.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.matradiagnosztika.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.matradiagnosztika.com\/en\/wp-json\/wp\/v2\/comments?post=1048"}],"version-history":[{"count":0,"href":"https:\/\/www.matradiagnosztika.com\/en\/wp-json\/wp\/v2\/pages\/1048\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.matradiagnosztika.com\/en\/wp-json\/wp\/v2\/pages\/1103"}],"wp:attachment":[{"href":"https:\/\/www.matradiagnosztika.com\/en\/wp-json\/wp\/v2\/media?parent=1048"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}